10KV cold shrinkable cable terminal, three core indoor terminal

Short Description:

  • 10KV series cold shrinkable cable termination kit and joints have the function of water-proof, stress control and insulation. With the excellent electrical and mechanical function, they can be used in all kinds of conditions for a long time. With light weight and easy mounting, they are widely used in power supply and petrochemicals, metallurgy, railway station, sea port and other constructions.
  • (1) The 10kV cable termination shall meet the following requirements:a) Outdoor cable terminations should be used when used outdoors, and cold-shrinkable cable terminations should be used when the ambient temperature difference is large.b) Choose indoor cable terminations when used indoors.c) The cable termination accessory grade uses a voltage grade of 15kV.d) The pipe diameter of the cable accessories needs to correspond to the core section of the cable.(2) For cable terminations where inflammable and explosive places are not allowed to have a fire, cold shrinkable cable termination accessories should be used.(3) The cable termination should adopt measures such as reinforced insulation, sealing moisture-proof, mechanical protection, etc. And It should have effective measures to improve the electric field concentration at the cable shielding end and ensure the distance between the outer insulation and the ground.

Product Detail

Product Tags

Product attributes

Model: NLS-10/3

Voltage: 10KV

Cable sectional area:25-400mm2 

10KV series applicable to 3.6/6kv, 6/6kv, 6/10kv, 8.7/15kv single-core three-core crosslinked power cable connection, play the role of sealing, insulation, stress evacuation. Especially suitable for petroleum, chemical, mining and other flammable and explosive places.

Product details

product description01

Product parameters

Product model:NLS-10/3      Rated voltage:10KV
Power-Frequency withstand voltage:10KV  

5 min power frequency withstand voltage:39KV no flashover and no breakdown

Partial discharge experiment:Discharge power at 30KV<10PC

15min DC withstand voltage:35KV no flashover and no breakdown
Tensile strength:>14 Impact pressure test:95KV±10 no flashover and no breakdown

Selection specification

Product model  

 Cable sectional area(mm2)

Unit

      NLS -10/3.1      

25-50

set

NLS -10/3.2

70-120

set

NLS -10/3.3

150-240

set

NLS -10/3.4

300-400

set